The PDF (Portable Document Format) was created in the early 1990’s as a brand new way for computer users to share documents between each other, especially if one person has a PC and the other a Mac. The shared PDF will display exactly the same on both computers.
PDF was created by Adobe and is no maintained by the International Organisation for Standardisation (ISO). It is a very interactive format and can contain buttons, links, audio, video, form fields, business logic and even electronic signatures. It can capture fonts, images as well as document texts and can also format documents from many different programs. Vivitar camera user manual.
Most PDF viewers or the software used to view the PDF is provided free of charge. There are many options available including Scribus, pdfTex, Adobe InDesign, Adobe Illustrator as well as Google Docs. The most popular however is Acrobat Reader DC.
Why we provide APC Power Supply manuals in PDF?:
AB1290 12V 9AH SLA Battery Replacement for APC Back-UPS Pro 1300/1500. 59 $38.99 $38.99. FREE Shipping. APC UPS Battery Replacement for APC Back-UPS Models BE500R, BE550MC, BK300C, BK350, BK500, BK500BLK, BK500M, BK500MC, BK500MUS, and SC420, SU420NET (RBC2) 4.3 out of 5 stars 366. Back-UPS®Pro 1300/1500 Installation and Operation Connect the battery Install PowerChute® Personal Edition Software APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the event of a power failure. Use the cable supplied with.
APC BACK-UPS 1200VA 120V. USB cable, User Manual. View Product Overview. Recommended replacement: APC Power-Saving Back-UPS Pro 1300. Back-UPS RS Features.
Power Saving Back-UPS XS 1500. Uninterruptible Power Supply (UPS). USB cable, User Manual. View Product Overview. Add to Favorites +.
· PDF’s are incredibly convenient and are easy to open and read by everyone, regardless of whether they have a PC or Mac.
· A PDF can be compressed into a file size that is easy to email while still maintaining the quality of the images.
· A PDF file can be made incredibly secure as you can set up passwords, digital signatures and even watermarks.
· A PDF allows you input many different types of content including images, animations, 3D models, hyperlinks and buttons.
PDF’s do have their drawbacks such as:
· PDF’s can often be difficult to edit or to extract information from as it’s original intention was to make the exchange of documents easier.
· There are different types of PDF’s, especially when searching or extracting information.
If you have a document that you would like to convert into a PDF, there are many sites online that will do the conversion for you for free and very quickly. The same is true if you are looking to convert from PDF format into a different format. This is often a much easier way to edit a PDF.
Page 2: Contact information, Limited warranty, Transfer voltage and sensitivity adjustment
Ensure the Back-UPS is securely connected to an AC outlet.
Back-UPS circuit breaker “tripped”.
Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch on the Back-UPS and plug in devices one at a time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not power essential equipment during an outage.
Equipment plugged into a Surge Only outlet.
Unplug device from 'Surge Only' outlet and move to a 'Battery Backup' outlet.
Back-UPS operates on battery although utility power exists.
Back-UPS circuit breaker “tripped”.
Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch the Back-UPS on and plug equipment in one-at-a-time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not provide expected backup time.
Back-UPS is heavily loaded.
Unplug non-essential equipment (printers, scanners, etc) from the Battery Backup outlets and plug into 'Surge Only' outlets.
Back-UPS battery cartridge is discharged due to recent power outage and has not had time to recharge.
Charge the battery cartridge for 8 hours. Back-UPS runtime is reduced until the battery cartridge is fully charged.
Battery has reached the end of its life.
Replace battery cartridge (see Order Replacement Battery Cartridge).
Red Replace Battery indicator is flashing. Green On Line indicator is on.
Internal battery cartridge is not connected.
Connect battery cartridge (see Connect Battery Cartridge).
Red Replace Battery indicator is on.
Battery has reached the end of its life.
Replace the battery cartridge (see OrderReplacement Battery Cartridge).
Red Overload indicator is on or flashing.
Connected equipment is drawing more power than the Back-UPS can provide.
Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets.
Green On Line indicator is on and all other front panel indicators are flashing.
Internal UPS fault.
Contact APC Technical Support (see Contact Information).
Battery
Cartridge
REPLACE BATTERY CARTRIDGE
ORDER REPLACEMENT BATTERY CARTRIDGE
The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC33. Please recycle spent battery cartridges.
APC and Back-UPS are registered trademarks of American Power Conversion.
All other trademarks are the property of their respective owners.
SERVICE
If the Back-UPS arrived damaged, notify the carrier.
If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken:
1.
Consult the Troubleshooting section to eliminate common problems.
2.
If the problem persists, go to http://www.apc.com/support/.
3.
If the problem still persists, contact APC Technical Support.
• Have the Back-UPS model number, serial number and date of purchase
available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address.
CONTACT INFORMATION
Technical Support
http://www.apc.com/support
Internet
http://www.apc.com
USA / Canada
1.800.800.4272
Mexico
292.0253 / 292.0255
Brazil
0800.12.72.1
Worldwide
Apc Back Ups 1300 Manual
+1.401.789.5735
LIMITED WARRANTY
The standard warranty is two (2) years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer.
In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as follows: 1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a
Standby Mode (no indicators lit).
2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the
Back-UPS will flash to acknowledge going into Programming Mode.
3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the
following table.
4. To select the Low Sensitivity setting, press the pushbutton until the yellow Allen bradley ultra 5000 user manual.
indicator is flashing.
5. To select the Medium Sensitivity setting, press the pushbutton until the yellow
and red indicators (second and third from the top) are flashing.
6. To select the High Sensitivity setting, press the pushbutton until yellow and both
red indicators (bottom three) are flashing.
7. To exit without changing the Sensitivity Setting, press the pushbutton until the
green indicator is flashing.
8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds,
the Back-UPS will exit Programming Mode; all indicators will extinguish.
Indicators
Flashing
Sensitivity
Setting
Input Voltage
Range
(for utility
operation)
RS Models
Input Voltage
Range
(for utility
operation)
XS Models
Use When
1
(yellow)
Low
78 - 150 Vac
78 - 142 Vac
Input voltage is
extremely low or high.
Not recommended for
computer loads.
2
(yellow,
and red)
Medium
(factory
default)
83 - 147 Vac
83 - 139 Vac
Back-UPS frequently
goes On Battery.
3
(yellow, red, and
red)
High
88 - 144 Vac
88 - 136 Vac
Connected equipment is
sensitive to voltage
fluctuations .
TRANSFER VOLTAGE AND SENSITIVITY ADJUSTMENT
Notice: This device complies with part 68 and 15 of the FCC rules.Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
On the bottom of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.